 NePortTM Series User Manual
Conextop Technologies Co., Ltd.
All rights reserved
I
Disclaimer
Copyright (c)2003 Conextop, Inc. All rights reserved. Conextop,NePort,with its patent-pending technology, and neChip are trNePortmarks of Conextop. All other trademarks are the property of their respective owners.
Contacts Conextop Ltd. Room 608, 6/F, Electric Building, High-tech Park, Nanshan, Shenzhen, China Phone: 86-755-26505615 Fax: 86-755-26505565
Technical Support Online: www.conextop.com/aboutus/contactus.htm Sales Offices For a current list of our domestic and international sales offices, go to the Conextop web site at www.conextop.com
II
Related Documentation
Manual CONEXTOP Manual CONEXTOP Commands NEPORT NEPORT User AT Description The manual provides a description of management functions of NEPORT series products. The manual provides a description of all the AT commands of NEPORT series product.
Content
Introduce the functions and configuration to readers.
readers
l l NEPORT product engineers Users who are familiar with network
Symbols Caution, means reader be careful. Improper operation may cause data loss or damage to equipment. Inhibition, means you must to do that. Note, means a complementary description.
Abbreviation Abbreviation Description IP Internet protocol TCP Transmission Control Protocol UDP User Datagram Protocol NTP Network time protocol DNS Domain Name System SMTP Simple mail transfer protocol UART DHCP Dynamic Host Configuration Protocol BOOTP BOOTstrap Protocol
III
Table of contents
Introduction............................................................................................................1-1 System Overview ...................................................................................................1-1 Features and Specifications....................................................................................1-2 1.2.1 Product Features....................................................................................................1-2 1.2.2 Product Specifications...........................................................................................1-2 1.3 Package Checklist ..................................................................................................1-3 Chapter 2 Getting Started .......................................................................................................2-1 2.1 Hardware connection and install............................................................................2-1 2.2 User Interface.........................................................................................................2-1 2.2.1 Local configuration via serial port ........................................................................2-1 2.2.2 Remote configuration via network........................................................................2-3 Chapter 3 Parameters..............................................................................................................3-1 3.1 Basic Settings.........................................................................................................3-1 3.2 Network..................................................................................................................3-2 3.2.1 Automatic IP address configuration ......................................................................3-2 3.2.2 Static IP address configuration..............................................................................3-2 3.2.3 Ethernet configuration...........................................................................................3-3 3.2.4 Network Type........................................................................................................3-3 3.3 PPPoE ....................................................................................................................3-4 3.3.1 PPPoE ...................................................................................................................3-4 3.3.2 PPPoE Status.........................................................................................................3-5 3.4 PPP.........................................................................................................................3-5 3.4.1 PPP........................................................................................................................3-5 3.4.2 PPP Status .............................................................................................................3-6 3.5 GPRS......................................................................................................................3-6 3.5.1 MSC Settings ........................................................................................................3-6 3.5.2 PPP........................................................................................................................3-7 3.5.3 PPP Status .............................................................................................................3-8 3.6 Server Settings .......................................................................................................3-8 3.7 Hostlist ...................................................................................................................3-9 3.7.1 Retry Settings........................................................................................................3-9 3.7.2 Host Information ...................................................................................................3-9 3.8 Serial Settings ......................................................................................................3-10 3.8.1 Enable Serial Port................................................................................................3-10 3.8.2 Port Settings ........................................................................................................3-10 3.8.3 Pack Control........................................................................................................3-11 3.9 Connection ...........................................................................................................3-11 3.9.1 Connection Protocol............................................................................................3-11 3.9.2 UDP.....................................................................................................................3-12 3.9.3 TCP .....................................................................................................................3-12 3.10 Email Settings ......................................................................................................3-15 3.10.1 Configure Server ...............................................................................................3-15 IV Chapter 1 1.1 1.2
3.10.2 Recipients..........................................................................................................3-16 3.11 Trigger Settings....................................................................................................3-16 3.11.1 Conditions .........................................................................................................3-16 3.11.2 Message Properties............................................................................................3-17 3.12 Input Trigger Settings...........................................................................................3-17 3.12.1 Serial Trigger.....................................................................................................3-17 3.12.2 Message Properties ...........................................................................................3-18 3.13 SNMP...................................................................................................................3-18 3.14 Password Setting..................................................................................................3-19 3.14.1 Change Password ..............................................................................................3-19 3.15 Power manage ......................................................................................................3-19 Chapter 4 Web Configuration .................................................................................................4-1 4.1 Basic Settings.........................................................................................................4-1 4.2 Network..................................................................................................................4-2 4.3 PPPoE ....................................................................................................................4-3 4.4 PPP.........................................................................................................................4-3 4.5 GPRS......................................................................................................................4-4 4.6 Server Settings .......................................................................................................4-5 4.7 Serial Channel ........................................................................................................4-6 4.7.1 Hostlist ..................................................................................................................4-6 4.7.2 Serial Settings .......................................................................................................4-7 4.7.3 Connection ............................................................................................................4-8 4.8 Email Settings ......................................................................................................4-10 4.9 Trigger Settings....................................................................................................4-11 4.10 Input Trigger Settings...........................................................................................4-12 4.11 SNMP Settings .....................................................................................................4-13 4.12 Password Setting..................................................................................................4-13 4.13 Power manage ......................................................................................................4-14 4.14 Logout ..................................................................................................................4-14 Chapter 5 TELNET Configuration .........................................................................................5-1 5.1 Basic Settings.........................................................................................................5-1 5.2 Network..................................................................................................................5-1 5.2.1 Static IP address configuration..............................................................................5-2 5.2.2 Dynamic IP address configuration ........................................................................5-2 5.2.3 Netcard setting ......................................................................................................5-2 5.2.4 Network type.........................................................................................................5-3 5.3 PPPoE ....................................................................................................................5-3 5.4 PPP.........................................................................................................................5-4 5.5 GPRS......................................................................................................................5-4 5.6 Server Settings .......................................................................................................5-5 5.7 Channel settings .....................................................................................................5-5 5.7.1 Hostlist ..................................................................................................................5-6 5.7.2 Serial Settings .......................................................................................................5-7 5.7.3 Connection ............................................................................................................5-7 V
Email Settings ........................................................................................................5-8 5.8.1 Email Settings .......................................................................................................5-9 5.8.2 Trigger Settings .....................................................................................................5-9 5.8.3 Input Trigger Settings..........................................................................................5-10 5.9 SNMP Settings .....................................................................................................5-10 5.10 User Manage ........................................................................................................5-11 5.11 Password Setting..................................................................................................5-12 5.12 Load factory default .............................................................................................5-12 5.13 Save and Reboot...................................................................................................5-12 5.14 View Settings .......................................................................................................5-13 Chapter 6 AT Command .........................................................................................................6-1 6.1 AT commands for parameters setting.....................................................................6-1 6.1.1 Basic Settings........................................................................................................6-1 6.1.2 Network.................................................................................................................6-1 6.1.3 PPPoE ...................................................................................................................6-1 6.1.4 PPP........................................................................................................................6-2 6.1.5 GPRS.....................................................................................................................6-2 6.1.6 Server Settings ......................................................................................................6-2 6.1.7 Host list .................................................................................................................6-2 6.1.8 Serial Settings .......................................................................................................6-2 6.1.9 Connection ............................................................................................................6-3 6.1.10 Email Settings .....................................................................................................6-3 6.1.11 Trigger Settings ...................................................................................................6-3 6.1.12 Input Trigger Settings..........................................................................................6-3 6.1.13 SNMP..................................................................................................................6-4 6.1.14 Password Setting .................................................................................................6-4 6.1.15 Special command ................................................................................................6-4 6.2 FTP AT command...................................................................................................6-4 6.2.1 Local and device ...................................................................................................6-5 6.2.2 Local and FTP server ............................................................................................6-5 6.2.3 Device and FTP server ..........................................................................................6-5 6.2.4 Read file procedure ...............................................................................................6-5 6.2.5 Write to file procedure ..........................................................................................6-6 Chapter 7 DeviceManagement ...............................................................................................7-1 7.1 Functions................................................................................................................7-1 7.1.1 Menu Items ...........................................................................................................7-1 7.1.2 Shortcuts Field ......................................................................................................7-3 7.1.3 Devices List View .................................................................................................7-3 7.2 Configuring Devices ..............................................................................................7-4 7.2.1 Login .....................................................................................................................7-4 7.2.2 Configure ..............................................................................................................7-4
5.8
VI
CONEXTOP NEPORT User Manual
Chapter 1 Introduction
Chapter 1 Introduction
1.1 System Overview
Conextop Technologies target at providing the most reliable and security M2M solution for the worldwide customers, and NePort is the most compact serial-IP module released in 2002, which has embedded all in a standard RJ45 connector, Neport is powered by our network processor SoC(Nechip), which includes a 10/100 MAC/PHY and 256 KB of SRAM on chip. It features a built-in web server for communications with a device via a standard Internet browser. Web capability can be used for remote configuration, real-time monitoring or troubleshooting. Neport has 512 KB of on-chip Flash for web pages and software upgrades. It acts as a dedicated co-processor that optimizes network activities permitting the host microprocessor to function at maximum efficiency. NePort series of Industrial Device Servers are a robust, feature-rich, high reliability, high-performance and cost effective way to network-enable equipment in an industrial automation environment. In accordance with the needs of users, NEPORT series can provide one or more serial ports, provide a cost-effective program for users to connect the RS232/RS422/RS485 serial equipment to network. NePort series integrates internal TCP / IP protocol stack to provide a complete network access and data transmission functions. And can provide a wide range of access means, including ETHERNET, PPP, PPPoE, GPRS, and users can choose one or more access methods according to actual demand. NePort Series provides users with a wealth of features and applications. in order to facilitate the using, provides convenient configuration including serial, HTTP, TELNET and other, the user can choose different ways to configure. And in order to facilitate the management of equipment, NEPORT Series also provides windows applications to manage multiple devices on the network through its centralized management and configuration functions. In order to compatible with traditional serial applications, NePort Series also provides users with the virtual serial port, so users do not need to modify existing applications to control the physical serial port through network.
1-1
CONEXTOP NEPORT User Manual
Chapter 1 Introduction
1.2 Features and Specifications
1.2.1 Product Features
The NEPORT Series products have the following features l Easy to connect to the Internet network l Serial transmission speed up to 921600bps l Supports 10/100 Mbps Ethernet--auto-detectable l Supports access to Internet network by PPP l Supports access to Internet network by PPPoE l Supports access to Internet network by GPRS l Supports RS-232/422/485 interface l Supports UDP Unicast/MulticastTCP SERVERTCP CLIENT working mode l Supports a wide range of configuration, including WEB, TELNET, and serial port l Supports virtual serial ports on Windows l Supports SNMP protocol and MIBII for network management l Supports SMTP protocol for email alerting l Supports TFTP and FTP protocol for web and firmware upgrading
1.2.2 Product Specifications
LAN l Type10M/100Mbps l InterfaceRJ45 Serial Interface l protocolsRS232/RS422/RS485 l Baud110bps-460800bps l Data bits5678 l Stop bits11.52 l ParityNone, Even, Odd, Space, Mark l Flow controlnode, software, hardware GSM/GPRS l Dual-Band GSM 900/1800 MHz, compliant to GSM phase 2/2+ l Output power: Class 4 (2W)/(EGSM900), Class 1(1W)/(GSM1800) l GPRS multi-slot class 10 l Mobile station class B Protocols l ICMPIPTCPUDPDHCP BOOTPTELNET l DNSSNMPHTTPSMTPSNTPARP 1-2
CONEXTOP NEPORT User Manual l l l PPPPAPCHAPLCPIPCP PPPOEFTPTFTP SSHSSLTLSHTTPSSMTPS
Chapter 1 Introduction
File System l FAT12/16/32 Others l dimension l power input: 3.3VDC, +/-5%;4.2VDC,+/-5% l power consumption: 250mA l Operation temperature: 0C to +70C (32F to 158F)5% to 95% RH l Store temperature: -20C to +85C (-4F to 185F)5% to 95% RH
1.3 Package Checklist
NEPORT serial device server User manual Serial Cable Power supply 1 1CD 1 1
1-3
CONEXTOP NEPORT User Manual
Chapter 2 Getting Started
Chapter 2 Getting Started
2.1 Hardware connection and install
Please refer to <>
2.2 User Interface
The device's configuration is stored in nonvolatile memory and is retained without power. You can change the configuration at any time. The unit performs a reset after you change and store the configuration. In order to improve the flexibility and convenience, NEPORT series of products provides a wide range of configuration tools for the user to choose, including: serial login configuration, WEB configuration, TELNET configuration, device manager configuration.
2.2.1 Local configuration via serial port
Connect serial port to NEPORT to build the local environment: 1, connect the computer serial port with NEPORT through a standard serial cable. 2, open the terminal simulation program in the computer, such as HyperTerm (HyperTerminal) on Windows system or Minicom on Linux system, to establish a new connection, select the actual serial port to use, and set the serial parameters as follows(take HyperTerm as a example):
Figure 2-1 new connection of COM
2-1
CONEXTOP NEPORT User Manual
Chapter 2 Getting Started
Figure 2-2 select port
Figure 2-3 port settings
2-2
CONEXTOP NEPORT User Manual
Chapter 2 Getting Started
Figure 2-4 terminal type settings 3When the devices rebooted, input in the terminal with 3 "+" (in intervals of not more than 1s), can enter the device configuration mode.
2.2.2 Remote configuration via network 2.2.2.1 Configure IP address of local PC
To configure TCP/IP manually: 1In Control Panel, open Network and Dial-up Connections . 2Right-click the local area connection you want to modify. 3Select Properties . 4In the General dialog box, select Internet Protocol (TCP/IP) . 5Click Properties .
2-3
CONEXTOP NEPORT User Manual
Chapter 2 Getting Started
6In the General dialog box, select the Use the following IP address option. 7Type the IP address, subnet mask, and default gateway in the respective boxes. The network administrator must provide these values for individual users, based on the IP addressing plan for your site. The value in the IP Address box identifies the IP address for the interface. The value in the Subnet Mask box is used to identify the network ID for the selected network adapter.
2-4
CONEXTOP NEPORT User Manual 8Click OK to save the IP addressing information. 9Click OK to save the connection properties.
Chapter 2 Getting Started
To configure a multihomed system using a single network adapter: 1In Control Panel, double-click Network and Dial-up Connections . 2Right-click the local area connection you want to modify, and then select Properties . 3Add TCP/IP configuration information for the first IP address, as described in Configure IP Address Manually. 4Click Advanced . 5Click Add to enter the IP address and subnet mask for each additional subnet.
2.2.2.2 Configuration via WEB
With integrated WEB server, users can easily access to the NEPORT Series product. 1Open your browser and type the IP address in address input box and press Enter; 2when connected successful, You may be prompted for your user name and password. Be sure to enter your new password. 3If the user name and password is correct, the main page of device will be opened. The left part of main page is the index column; the right part is the overview information about the system.
2-5
CONEXTOP NEPORT User Manual
Chapter 2 Getting Started
Figure 2-5 HTTP main menu
2.2.2.3 Configuration via TELNET
With integrated TELNET server, NEPORT series product supports multi-user login at the same time, and supports a wide range of TELNET client, you can use command line tools as TELNET client under the Windows and Linux. In the following we use Windows as an example to show the detailed operation of TELNET command line tools. 1Open "Run" under the "Start" menu, type "cmd" to start command-line tool .
Figure 2-6 run the cmd tool
2 Under the command line type "telnet dd.dd.dd.dd" and enter, in which "dd.dd.dd.dd" refers to the device address to login, the device address is "192.168.0.251" below. 2-6
CONEXTOP NEPORT User Manual
Chapter 2 Getting Started
Figure 2-7 TELNET connect to server
3After that, please according to the screen prompt to enter a user name and password to complete the login.
Figure 2-8 TELNET login page
4When authenticate success, the main menu will show as follows:
Figure 2-9 TELNET main menu
2.2.2.4 Configuration via Device manager
NEPORT series products support PC client management software "DeviceManagement" to manage and configure devices. 1, according to the products installation files of "DeviceManagement" that found in the accompanying software package and begin software installation. 2-7
CONEXTOP NEPORT User Manual
Chapter 2 Getting Started
2, after the success of the software installation, there is a shortcut will be generated on the desktop, through the shortcut or through the "Start" menu to find DeviceManagement menu items, you can open DeviceManagement software interface as follows:
Figure 2-10 Device Manager
2-8
CONEXTOP NEPORT User Manual
Chapter 3 Parameters
Chapter 3 Parameters
NEPORT series products with rich functions in actual use, the user needs to configure it as needed, select the required function, cancel the function does not required. NEPORT Series products have a variety of means of configuration, In order to know the content of configuration, in the following chapter, the parameters of the equipment will be introduced one by one.
Note
Configuration tool Introduced in the follow-up such as WEB, TELNET, have the same sub-sections of this chapter.
3.1 Basic Settings
parameter Server Name contents The name of device server Option value: any string length less than 14 bytes. Default value: NULL Notes: it will not change when load factory setting. Set the current time of device Time Zone User selectable time zone. Local Time System time. Time Server Server name used to synchronize the time. Enable or disable web service. Enable or disable telnet service. Some of the old terminal may be required before the connection is established in the terminal type of transmission. You may need to refer to the documentation to determine the appropriate type. In most applications of modern terminals, this is not a necessity, can not serve any purpose. Suggested default value:VT100. Table 3-1 basic setting parameters
Time
Web Console Telnet Console Terminal Type
3-1
CONEXTOP NEPORT User Manual
Chapter 3 Parameters
Caution:
As the two remote access methods, if the HTTP and TELNET are disabled, the device can not be accessed by network.
3.2 Network
3.2.1 Automatic IP address configuration
parameter BOOTP DHCP AutoIP DHCP Host Name contents Whether or not to allow BOOTP to obtain IP address. Whether or not to allow DHCP to obtain IP address. Whether or not to allow AutoIP to obtain IP address. DHCP server host name.
Table 3-2 Automatic IP address configuration
Note: DHCP protocol is developed based on the BOOTP protocol and is compatible with BOOTP protocol, if is not clear, the best choice is DHCP, because BOOTP protocol protocol can not be compatible with DHCP.
3.2.2 Static IP address configuration
parameter IP Address Subnet Default Gateway Preferred DNS server Alternate DNS server Static ip address of device. Ip address network mask Gateway of network. The 1st DNS server to use when query. The second DNS server to use when query. Table 3-3 static IP address contents
3-2
CONEXTOP NEPORT User Manual
Chapter 3 Parameters
Inhibition: If you choose to use manually configure IP addresses, IP address can not the same as the others in the same network, otherwise it will leading to unpredictable consequences.
3.2.3 Ethernet configuration
parameter Auto Negotiate contents Auto-negotiation is selected, the device will auto-negotiate with the network node of the network; uncheck it will using the designated mode. Option values: Enable/Disable Default value: Enable Netcard working speed. Option values(bps): 10M/100M. Default value: 10M Netcard working mode. Option values: Full or Half. Default value: Full Mac address of netcard. Option value: valid mac address in "xx.xx.xx.xx.xx.xx" format. Default value: None. Table 3-4 ethernet configuration
Speed
Duplex
MAC Address
Inhibition: In the LAN, MAC address are used to distinguish between the various devices or PC, MAC address of device can not be the same with any other device or PC machine in the network.
3.2.4 Network Type
parameter Ethernet PPP PPPoE GPRS contents Whether or not to enable ethernet Whether or not to enable PPP dialup network Whether or not to enable PPPoE dial-up network Whether or not to enable GPRS Table 3-5 network type
3-3
CONEXTOP NEPORT User Manual
Chapter 3 Parameters
3.3 PPPoE
3.3.1 PPPoE
parameter User Name contents User name of dial-up account Option value: any string of length less than 31 bytes. Default value: "admin" Password of dial-up account. Option value: any string of length less than 21 bytes. Default value: "admin" Work mode of dial-up. Option value: Disable Disable the PPPoE dial-up function, the device can not access network through PPPoE. Auto Dial: In such mode, the device will try to keep the dial-up connection. Once the connection is disconnect, it will try to connect again until connect success. Dial on Demand: When the device have to send data to network, but dial-up connection is disconnected, it will dial up to connect. Should use in cooperate with Idle Time. Adaptive: The device will use PPPoE dial-up connection or LAN to transmit data automatically. Default value: Disable. Times of redial when failed to login, Only valid in Dial on Demand mode. Option value: 0-255 Default value: 0 Interval time of redial when failed to login. Option value: 0-255 Default value: 0 When the dial-up connection is idle after idle time, it will be compelled to disconnect. Option value(secs): 0-65535 Default value: 0 Table 3-6 PPPoE dial-up settings
Password
Work Mode
Max Redial Times
Redial Interval
Idle Time
3-4
CONEXTOP NEPORT User Manual
Chapter 3 Parameters
3.3.2 PPPoE Status
PPPoE status parameters are read-only, to display status of PPPoE dial-up connection. parameter Link Status PPPoE IP PPPoE Gateway PPPoE DNS1 PPPoE DNS2 contents Status of dial-up connection. Option value: deactive/linking/active. Default value: deactive. IP address of dial-up connection. Gateway of dial-up connection. Preferred DNS address of dial-up connection. Alternative DNS address of dial-up connection. Table 3-7 PPPoE state
3.4 PPP
3.4.1 PPP
parameter User Name contents User name of dial-up account Option value: any string of length less than 31 bytes. Default value: "admin" Password of dial-up account. Option value: any string of length less than 21 bytes. Default value: "admin" Work mode of dial-up. Option value: Disable Disable the PPP dial-up function, the device can not access network through PPP. Auto Dial: In such mode, the device will try to keep the dial-up connection. Once the connection is disconnect, it will try to connect again until connect success. Dial on Demand: When the device has to send data to network, but dial-up connection is disconnected, it will dial up to connect. Should use in cooperate with Idle Time. Adaptive: The device will use PPP dial-up connection or LAN to transmit data automatically. Default value: Disable. 3-5
Password
Work Mode
CONEXTOP NEPORT User Manual
Chapter 3 Parameters
Max Redial Times
Times of redial when failed to login, Only valid in Dial on Demand mode. Option value: 0-255 Default value: 0 Interval time of redial when failed to login. Option value: 0-255 Default value: 0 When the dial-up connection is idle after idle time, it will be compelled to disconnect. Option value(secs): 0-65535 Default value: 0 Which serial port is used for dial-up. Option value: vary according to firmware. Default value: vary according to firmware.
Table 3-8 PPP dial-up
Redial Interval
Idle Time
COM
3.4.2 PPP Status
PPPoE status parameters are read-only, to display status of PPPoE dial-up connection. parameter contents Link Status PPP IP PPP Gateway PPP DNS1 PPP DNS2 Status of dial-up connection. Option value: deactive/linking/active. Default value: deactive. IP address of dial-up connection. Gateway of dial-up connection. Preferred DNS address of dial-up connection. Alternative DNS address of dial-up connection. Table 3-9 PPP status
3.5 GPRS
3.5.1 MSC Settings
parameter Access Point Name contents The name used to identify a general packet radio service (GPRS) bearer service in the GSM mobile network. The APN defines the type of service that is provided in the packet data connection. Option values: Any string provided by mobile operator. Default value: CMNET Dial string. Option values: any string provided by mobile operator. 3-6
Service Code
CONEXTOP NEPORT User Manual Default value: *99***1# SIM/UIM PIN
Chapter 3 Parameters
SIM PIN1 Option values: any string provided by mobile operator. Default value: NULL Table 3-10 GPRS mobile services center
3.5.2 PPP
parameter User Name contents User name of dial-up account Option value: any string of length less than 31 bytes. Default value: "admin" Password of dial-up account. Option value: any string of length less than 21 bytes. Default value: "admin" Work mode of dial-up. Option value: Disable disable the PPP dial-up function, the device can not access network through PPP. Auto Dial: In such mode, the device will try to keep the dial-up connection. Once the connection is disconnect, it will try to connect again until connect success. Dial on Demand: When the device has to send data to network, but dial-up connection is disconnected, it will dial up to connect. Should use in cooperate with Idle Time. Adaptive: The device will use PPP dial-up connection or LAN to transmit data automatically. Default value: Disable. Times of redial when failed to login, Only valid in Dial on Demand mode. Option value: 0-255 Default value: 0 Interval time of redial when failed to login. Option value: 0-255 Default value: 0 When the dial-up connection is idle after idle time, it will be compelled to disconnect. Option value(secs): 0-65535 Default value: 0 3-7
Password
Work Mode
Max Redial Times
Redial Interval
Idle Time
CONEXTOP NEPORT User Manual COM
Chapter 3 Parameters
Which serial port is used for dial-up. Option value: vary according to firmware. Default value: vary according to firmware. Table 3-11 GPRS PPP dial-up
3.5.3 PPP Status
PPPoE status parameters are read-only, to display status of PPPoE dial-up connection. parameter Link Status PPP IP PPP Gateway PPP DNS1 PPP DNS2 contents Status of dial-up connection. Option value: deactive/linking/active. Default value: deactive. IP address of dial-up connection. Gateway of dial-up connection. Preferred DNS address of dial-up connection. Alternative DNS address of dial-up connection. Table 3-12 GPRS PPP status
3.6 Server Settings
parameter ARP cache Timeout(secs) contents Timeout time of ARP entry. When timeout, the system will renew the ARP entry, if fail, the entry will be deleted. Alternative values(secs): 0-255. Default value: 255 CPU running mode. Alternative values: High/Normal. Default value: Normal. Note: if in high speed mode, it will cost more power and more faster. Web server's service port. Alternative values: 1-65535. Default value: 80 The size of maximum transmit unit in bytes. Can not be modified. Table 3-13 server settings
CPU Performance Mode
HTTP Server Port
MTU Size
3-8
CONEXTOP NEPORT User Manual
Chapter 3 Parameters
3.7 Hostlist
3.7.1 Retry Settings
parameter Retry Counter contents The re-connect times when the device connects the remote host fails. When the number of retries reached but the device still unable to connect to the remote host, it will select other address in the host list to connect; the above process will be repeated until a successful connection to a host in the list of hosts. It's value must be within 0 to 255, 0 means no retry. If the device connect the remote host fails, the timeout to re-trying to connect. Retry timeout when still can not connect to reach the remote host, the module will select the host list of other addresses to connect to remote host; the above process will be repeated until a successful connection to a host in the list of hosts.
Table 3-14 retry settings
Retry Timeout
Note:
When reach retry counter or retry timeout, the device will give up retry the same host and try another host.
3.7.2 Host Information
parameter Host Address Port Backup link Host's IP address. Host's port number. Whether or not to support a backup link. If enabled, the device will establish 2 connections and transmit data on both. Otherwise, only one connection can be established in a time. Table 3-15 remote host information contents
3-9
CONEXTOP NEPORT User Manual
Chapter 3 Parameters
3.8 Serial Settings
3.8.1 Enable Serial Port
parameter Enable Serial Port contents Whether or not enable serial port Option value: Enable/Disable Default value: Enable Table 3-16 enable serial port
Caution:
When the serial port is disabled, then it can not be used to send and receive data, also can not use the AT commands and serial login capabilities via it.
3.8.2 Port Settings
parame ter Protoc ol FIFO contents Protocol used in serial port communication. Option values: RS232/RS422/RS485. Default value: RS232. Serial port hardware FIFO length. Option values: 4, 8, 16. Default value: 8 Option values: None/Software/Hardware. Default value: None.
Flow Contro l Baud Rate
Data Bits Parity Stop bits
Serial port baud rate. Option values(bps): 110/134/150/300/600/1200/1800/2400/4800/7200/9600/14400/19200/38400/57600/11 5200/230400/460800/921600 Default value: 9600 Data bits used in serial communication. Option values(bit):8/7/6/5 Default value:9 Option values: NONE/ODD/EVEN/MARK/SPACE. Default value: NONE. Option values (bit): 0/1.5/2. Default value: 0. 3-10
CONEXTOP NEPORT User Manual
Table 3-17 serial port settings
Chapter 3 Parameters
Caution:
Configuration at both ends of the serial line must be the same.
3.8.3 Pack Control
parameter Enable Packing contents Whether or not to enable packing function. How to packing serial data stream is dependant on the following parameters. Option value: Enable/Disable Default value: Disable Maximum time for inactivity. If there is any data on serial port's receive buffer, they will be packed and sent to network. Option value(ms): 12/11/10 Default value: 12 If enabled, used the two match bytes to indicate the beginning and end of a series of data to be sent as one group. Otherwise, used the first match byte to indicate the end of a series of data to be sent as one group. Option value: Enable/Disable. Default value: Disable. After the detection of the byte sequence, indicates whether to send the data frame or the entire buffer. Option value: YES/NO. Default value: YES Used to indicate the beginning and the end of a series of data to be sent as one group. Option value(HEX): 0x00-0xFF Default value: 0x00 Table 3-18 serial packing settings
Idle Gap Time
Match 2 Byte Sequence
Send Frame Only
Match Byte
3.9 Connection
3.9.1 Connection Protocol
parameter Protocol Network protocol Option values: TCP/UDP Default value: TCP 3-11 contents
CONEXTOP NEPORT User Manual
Chapter 3 Parameters
Table 3-19 connection protocol
3.9.2 UDP 3.9.2.1 Datagram Mode
parameter Datagram Type contents Type of udp datagram. Option values: Uniunicast type. Multimulti-cast type. Default value: Uni. Whether to accept UDP data from remote host. Option values: YES/NO. Default value: YES Table 3-20 UDP datagram mode
Accept Incoming
3.9.2.2 Multi-Cast Configuration
parameter Local Port Remote Port Net Segment Remote host's port. Remote host's multi-cast address. Table 3-21 UDP multi-cast configuration contents Local port used to communicate with remote.
3.9.2.3 Uni-Cast Device Address Table
parameter Device Address Port Local Port contents Remote host's uni-cast address. Remote host's port in uni-cast communication. Local port used in uni-cast communication.
Table 3-22 UDP uni-cast device address table
3.9.3 TCP 3.9.3.1 Connect Mode
parameter Worked As Work mode of TCP. 3-12 contents
CONEXTOP NEPORT User Manual
Chapter 3 Parameters
Option values: ServerAs a server and accept new connection of remote. ClientAs a client, connect to remote host initiatively. Both Default: Server. Table 3-23 TCP connection mode
3.9.3.2 Active Connection
parameter Active Connect contents When work as a client, when to connect to remote host. Option values: NoneDisabled. With Any Character: when receive any character in serial port. With Start Character: when receive a specified character in serial port. Auto Start: auto start when system starts and tries to keep. Default value: None. The specified character to trigger initiative connects. The character must in HEX format.
Table 3-24 TCP active connection
Start Character
3.9.3.3 Connection Configuration
parameter Local Port contents When working as server, it is the listening port; When working as client, it is the local port of connection. Value range: 0-65535 Default value:0 The remote host's communication port. The host name or IP address of remote. When a TCP connection is established, the device will send a character `C' to serial port. When a TCP connection is disconnected, the device will send a character `D' to serial port. Alternative values: None: disable. ACT: enable. Default value: None. Whether or not to use host list table. Alternative values: YES/NO. Default value: NO. 3-13
Remote Port Remote Host Connect Response
Use Host list
CONEXTOP NEPORT User Manual
Chapter 3 Parameters
Table 3-25 TCP connection configuration
3.9.3.4 Disconnect Mode
parameter On DSR Drop contents All TCP connection will be disconnect when serial's DSR pin `s voltage transfer from high to low. Alternative value: Enable/Disable. Default value: Disable. Note: Only work on modem port. The TCP connection will closes even if the remote site does not acknowledge the disconnect request. Option value: Enable/Disable. Default value: Disable. Disconnect all connection when receive a character EOT(ctrl+D) on the serial port. Alternative value: Enable/Disable. Default value: Disable When the TCP connection is idle (without any data transmission) for a specified time, disconnect the connection automatically. If the specified time is 0, disable this function. Alternative values: 0-255. Default value: 255. Table 3-26 TCP disconnect mode
Hard Disconnect
Check EOT(Ctr-D)
Inactivity Timeout
3.9.3.5 Flush Input Buffer
parameter With Active Connect contents Whether or not to clear the input buffer of serial port when the device initiative connect to the remote. Option value: Enable/Disable. Default value: Disable. Whether or not to clear the input buffer of serial port when a remote host initiative connect to the device. Option value: Enable/Disable. Default value: Disable. Whether or not to clear the input buffer of serial port when the connection of the device is disconnected. Option value: Enable/Disable. Default value: Disable. Table 3-27 flush input buffer of serial port
With Passive Connect
At Time of Disconnect
3-14
CONEXTOP NEPORT User Manual
Chapter 3 Parameters
3.9.3.6 Flush Output Buffer
parameter With Active Connect contents Whether or not to clear the output buffer of serial port when the device initiative connect to the remote. Option value: Enable/Disable. Default value: Disable. Whether or not to clear the output buffer of serial port when a remote host initiative connect to the device. Option value: Enable/Disable. Default value: Disable. Whether or not to clear the output buffer of serial port when the connection of the device is disconnected. Option value: Enable/Disable. Default value: Disable. Table 3-28 flush output buffer of serial port
With Passive Connect
At Time of Disconnect
3.10 Email Settings
3.10.1 Configure Server
parameter SMTP Domain Name contents Domain name or IP address of SMTP server. Option values: any domain name string length less than 31bytes. Default value: NULL Port of SMTP server. Option values: 1-65535 Default value: 25 User email address used to send mail. Option values: any email address string length less than 31 bytes. Default value: NULL Name of user account. Option values: any string length less than 31 bytes. Default value: NULL Password of user account. Option values: any string length less than 31 bytes. Default value: NULL Table 3-29 email server settings
SMTP Port
Email Address
Username
Password
3-15
CONEXTOP NEPORT User Manual
Chapter 3 Parameters
3.10.2 Recipients
parameter Recipient 1 Email contents Enter the email address designated to receive email notifications. Option values: any email address string length less than 31 bytes. Default value: NULL Enter the email address designated to receive email notifications. Option values: any email address string length less than 31 bytes. Default value: NULL Enter the email address designated to receive email notifications. Option values: any email address string length less than 31 bytes. Default value: NULL
Table 3-30 email recipients
Recipient 2 Email
Recipient 3 Email
3.11 Trigger Settings
3.11.1 Conditions
parameter Cold start contents Whether or not to send a email when the device is cold start (hardware reset). Option value: Mail On/Mail Off. Default value: Mail Off. Whether or not to send a email when the device is warm start (software reset). Option value: Mail On/Mail Off. Default value: Mail Off. Whether or not to send a email when there is a login authenticate failure. Option value: Mail On/Mail Off. Default value: Mail Off. Whether or not to send a email when the device's IP address is changed. Option value: Mail On/Mail Off. Default value: Mail Off. Whether or not to send a email when the device's login 3-16
Warm start
Login auth failure
IP address changed
Password changed
CONEXTOP NEPORT User Manual
Chapter 3 Parameters
password is changed. Option value: Mail On/Mail Off. Default value: Mail Off. DCD Changed Whether or not to send a email when the DCD state of modem port is changed. Option value: Mail On/Mail Off. Default value: Mail Off. Whether or not to send a email when the DSR state of modem port is changed. Option value: Mail On/Mail Off. Default value: Mail Off. Table 3-31 normal email trigger event
DSR Changed
3.11.2 Message Properties
parameter Subject contents Subject of mail to send. Option values: any string length less than 31 bytes. Default value: NULL Mail priority. Option values: High/Low/Normal. Default value: Normal. The minimum time allowed between individual triggers. If a trigger event occurs within the minimum interval since the last trigger, it is ignored. Option value(secs): 0-255 Default value: 0 Table 3-32 normal email trigger message properties
Priority
Min.Notification Interval
3.12 Input Trigger Settings
3.12.1 Serial Trigger
parameter Enable Serial Input Trigger contents Whether or not to enable email trigger of serial port input. Option value: Enable/Disable. Default value: Disable. The channel number used as a serial input trigger. Option value: according to different version of product. Default value: according to different version of product. Continuous characters number used to trigger email. Option value: Two Bytes/Three Bytes. 3-17
Channel
Data Size
CONEXTOP NEPORT User Manual Default value: Two Bytes. Match Data
Chapter 3 Parameters
Character used to trigger email. Option value(in hex): 0x00-0xFF Default value: 0x00 Table 3-33 serial input trigger
3.12.2 Message Properties
parameter Subject contents Subject of mail triggered by serial input data. Option value: any string length less than 31 bytes. Default value: NULL Priority of mail triggered by serial input data. Option value: High/Normal/Low. Default value: Normal. The minimum time allowed between individual serial input triggers. If a trigger event occurs within the minimum interval since the last trigger, it is ignored. Option value(secs): 0-255 Default value:0 Table 3-34 serial input trigger message properties
Priority
Min.Notification Interval
3.13 SNMP
parameter Disable SNMP contents Whether or not disable SNMP. Option value: YES/NO. Default value: YES. String used to read SNMP MIB variables. Option values: any string length less than 17bytes. Default value: public String used to write SNMP MIB variables. Option values: any string length less than 17bytes. Default value: private Contact name of SNMP MIBII. Option values: any string length less than 31bytes. Default value: NULL Location of SNMP MIBII. Option values: any string length less than 17bytes. Default value: Shenzhen The host IP address of SNMP TRAP message. Option value: any string in IP address format. 3-18
Read Community
Write Community
Contact Name
Location
Notification Host
CONEXTOP NEPORT User Manual Default value: 0.0.0.0 Table 3-35 SNMP
Chapter 3 Parameters
3.14 Password Setting
3.14.1 Change Password
parameter Username contents User name for web login. Option values: any string length less than 11 bytes. Default value: admin Current password for web login, only need when change password.. Option values: any string length less than 11 bytes. Default value: admin New password for web login when change password. Option values: any string length less than 11 bytes. Default value: admin Confirm new password for web login when change password. Option values: any string length less than 11 bytes. Default value: admin Table 3-36 change password
Old Password
New Password
Retry Password
Caution: If the password is lost, then press the default button to restore the factory value of parameters, use the default user name and password "admin" on the login again.
3.15 Power manage
parameter Load defaults Load defaults and reboot Reboot Save and reboot Restore factory settings. Restore factory settings and reboot. Just reboot the device. Save the parameters and reboot. Table 3-37 power manage contents
3-19
CONEXTOP NEPORT User Manual
Chapter 4 Web Configuration
Chapter 4 Web Configuration
Through a Web browser to configure the device is the most intuitive and convenient way. Here recommend the use of the mainstream browser, such as IE or FireFox for a visit. In the following sections about WEB configuration, if there is no special note, the user need clicks on the "Submit" button of the page to submit data, configuration only take effect after the restart. Configuration of device have been carried out in accordance with the relevant portfolio, located in different sub-page, please click on the left column of the corresponding sub-index into the configuration menu, the specific configuration items will be explained in the following sections of this chapter, and provide a description page, click the "Help" button next to "submit" on the page to view. One suggestion was that in the configuration of device, please first finish modify all the configuration, and then click "Apply Settings / Restart" to restart, to improve the efficiency.
Note:
Map page of this chapter are for reference only, there are may be small differences in the content and WEB page in actual products.
4.1 Basic Settings
In the main menu click on "Basic Settings" link, basic configuration page will show as follows:
Figure 4-1 HTTP basic settings page
4-1
CONEXTOP NEPORT User Manual
Chapter 4 Web Configuration
Please refer to section 3.1 to see the description of the parameters.
4.2 Network
In the main menu click on "Network" link, network configuration page will show as follows:
10M
100M
Figure 4-2 HTTP network settings page
There is three parts in this page for configuration: IP configuration, Ethernet Configuration, Network Type. Please refer to the description of the parameters in section3.2, 3.2.3, 3.2.4.
4-2
CONEXTOP NEPORT User Manual
Chapter 4 Web Configuration
4.3 PPPoE
In the main menu click on "PPPoE" link, PPPoE configuration page will show as follows:
Figure 4-3 HTTP PPPoE settings page
There is two parts in this page for configuration: PPPoE configuration, PPPoE status. Please refer to the description of the parameters in section3.3.1, 3.3.2.
4.4 PPP
In the main menu click on link "PPP", PPP configuration page will show as follows:
4-3
CONEXTOP NEPORT User Manual
Chapter 4 Web Configuration
Figure 4-4 HTTP PPP settings page
There is two parts in this page for configuration: PPP configuration, PPP status. Please refer to the description of the parameters in section3.4.1, 3.4.2.
4.5 GPRS
In the main menu click on link "GPRS", GPRS configuration page will show as follows:
4-4
CONEXTOP NEPORT User Manual
Chapter 4 Web Configuration
Figure 4-5 HTTP GPRS settings page
There is three parts in this page for configuration: MSC settings, GPRS configuration and GPRS status. Please refer to the description of the parameters in section 3.5.1, 3.5.2, 3.5.3.
4.6 Server Settings
In the main menu click on link "Server", server configuration page will show as follows:
4-5
CONEXTOP NEPORT User Manual
Chapter 4 Web Configuration
Figure 4-6 HTTP server settings page
There is only one part in this page for configuration: server configuration. Please refer to the description of the parameters in section 3.6.
Note:
If value of HTTP Server Port is other than 80, please attach port number when access WEB in address format http://address:port.
4.7 Serial Channel
The NEPORT series, each serial port on behalf of a channel, includes 3 parts to be configured: serial port settings, connection settings, remote host configuration.
4.7.1 Hostlist
In the main menu click on link "Hostlist", hostlist configuration page will show as follows:
4-6
CONEXTOP NEPORT User Manual
Chapter 4 Web Configuration
Figure 4-7 HTTP host list settings page There is two parts in this page for configuration: Retry settings and Host information. Please refer to the description of the parameters in section3.7.1, 3.7.2.
Note:
Host lists are valid only when in TCP client mode.
4.7.2 Serial Settings
In the main menu click on link "Serial setting", serial port configuration page will show as follows:
4-7
CONEXTOP NEPORT User Manual
Chapter 4 Web Configuration
Figure 4-8 HTTP serial settings page
There is two parts in this page for configuration: Port settings and Pack Control. Please refer to the description of the parameters in section 3.8.1, 3.8.2, 3.8.3.
4.7.3 Connection 4.7.3.1 Connection Protocol
Click on the drop list of Connection Protocol, you will see the two choice: TCP and UDP. There is different page for you when select different item.
4.7.3.2 UDP
Select UDP as connection protocol, the UDP page will show as follow:
4-8
CONEXTOP NEPORT User Manual
Chapter 4 Web Configuration
Figure 4-9 HTTP UDP settings page
There is three parts in this page for configuration: Datagram Mode, Endpoint configuration and Device Address Table. Please refer to the description of the parameters in section 3.9.2.
4.7.3.3 TCP
Select TCP as connection protocol, the TCP page will show as follow:
4-9
CONEXTOP NEPORT User Manual
Chapter 4 Web Configuration
Figure 4-10 HTTP TCP settings page
There is four parts in this page for configuration: Connect Mode, Endpoint configuration, Disconnect Mode and Flush Mode. Please refer to the description of the parameters in section 3.9.3.
4.8 Email Settings
In the main menu click on link "Email settings", email configuration page will show as follows:
4-10
CONEXTOP NEPORT User Manual
Chapter 4 Web Configuration
Figure 4-11 HTTP email settings page
There is two parts in this page for configuration: Configure Server and Recipients. Please refer to the description of the parameters in section 3.10.
4.9 Trigger Settings
In the main menu click on link "trigger settings" under Email, trigger settings page will show as follows:
4-11
CONEXTOP NEPORT User Manual
Chapter 4 Web Configuration
Figure 4-12 HTTP email trigger settings page
There is two parts in this page for configuration: Conditions and Message Properties. Please refer to the description of the parameters in section3.11.
4.10 Input Trigger Settings
In the main menu click on link "Input trigger settings" under Email, input trigger settings page will show as follows:
Figure 4-13 HTTP email input trigger settings page
There is two parts in this page for configuration: Conditions and Message Properties. Please refer to the description of the parameters in section3.12. 4-12
CONEXTOP NEPORT User Manual
Chapter 4 Web Configuration
4.11 SNMP Settings
In the main menu click on link "SNMP", SNMP configuration page will show as follows:
Conextop
Figure 4-14 HTTP SNMP settings page
There is only one part in this page for configuration: SNMP settings. Please refer to the description of the parameters in section 3.13.
4.12 Password Setting
In the main menu click on link "Password settings", password configuration page will show as follows:
Figure 4-15 HTTP password settings page
There is only one part in this page for configuration: change password. Please refer to the description of the parameters in section3.14.
4-13
CONEXTOP NEPORT User Manual
Chapter 4 Web Configuration
Note:
You can only modify the password of current user on this view.
4.13 Power manage
In the main menu click on link "Power manage", system reset configuration page will show as follows:
Figure 4-16 HTTP power manage page
There is only one part in this page for configuration: power manage. Please refer to the description of the parameters in section3.15.
Caution:
Before system restarting, please check whether there is any parameters need to save, if so please select "Save and reboot" option, otherwise the configuration will not saved.
4.14 Logout
Click "Logout" in the menu bar, enter the "log out" page, the page will be shut down after 3 seconds, the user needs to re-verify when login again, as follows:
Figure 4-17 HTTP logout page
4-14
CONEXTOP NEPORT User Manual
Chapter 5 TELNET Configuration
Chapter 5 TELNET Configuration
Telnet (teletype network) is a network protocol used on the Internet or local area networks to provide a bidirectional interactive communications facility. Typically, telnet provides access to a command-line interface on a remote host via a virtual terminal connection which consists of an 8-bit byte oriented data connection over the Transmission Control Protocol (TCP). User data is interspersed in-band with TELNET control information.
5.1 Basic Settings
Change to the main menu view, enter the shortcut keys before "basic settings", then changed to the basic settings view, as follows:
Figure 5-1 TELNET basic settings view
Please refer to the description of the parameters in section3.1.
5.2 Network
Change to the main menu view, enter the shortcut keys before "Network", then changed to the network settings view, as follows:
5-1
CONEXTOP NEPORT User Manual
Chapter 5 TELNET Configuration
Figure 5-2 TELNET network settings view
5.2.1 Static IP address configuration
Change to the network setting view, enter the shortcut keys before "Use static IP address", then changed to the static IP address settings view, as follows:
Figure 5-3 TELNET static IP address view
Please refer to the description of the parameters in section3.2.
5.2.2 Dynamic IP address configuration
Change to the network setting view, enter the shortcut keys before "Obtain IP automatically", then changed to the dynamic IP address settings view, as follows:
Figure 5-4 TELNET dynamic IP address view
Please refer to the description of the parameters in section3.2.
5.2.3 Netcard setting
Change to the network setting view, enter the shortcut keys before "Speed/duplex", then changed to the netcard settings view, as follows:
5-2
CONEXTOP NEPORT User Manual
Chapter 5 TELNET Configuration
Figure 5-5 TELNET netcard settings view
Please refer to the description of the parameters in section3.2.
5.2.4 Network type
Change to the network setting view, enter the shortcut keys before "Network Type", then changed to the network type settings view, as follows:
Figure 5-6 TELNET network type view
Please refer to the description of the parameters in section3.2
5.3 PPPoE
Change to the main menu view, enter the shortcut keys before "PPPoE Settings", then changed to the PPPoE settings view, as follows:
5-3
CONEXTOP NEPORT User Manual
Chapter 5 TELNET Configuration
Figure 5-7 TELNET PPPoE view
Please refer to the description of the parameters in section3.3.
5.4 PPP
Change to the main menu view, enter the shortcut keys before "PPP Settings", then changed to the PPP settings view, as follows:
Figure 5-8 TELNET PPP view
Please refer to the description of the parameters in section 3.4.
5.5 GPRS
Change to the main menu view, enter the shortcut keys before "GPRS Settings", then 5-4
CONEXTOP NEPORT User Manual changed to the GPRS settings view, as follows:
Chapter 5 TELNET Configuration
Figure 5-9 TELNET GPRS view
Please refer to the description of the parameters in section 3.5.
5.6 Server Settings
Change to the main menu view, enter the shortcut keys before "Server Settings", then changed to the Server settings view, as follows:
Figure 5-10 TELNET server settings view Please refer to the description of the parameters in section 3.6.
5.7 Channel settings
Change to the main menu view, enter the shortcut keys before "Serial Channel", then changed to the serial channel view, as follows:
5-5
CONEXTOP NEPORT User Manual
Chapter 5 TELNET Configuration
Figure 5-11 TELNET serial channel view
Change to the serial channel view, enter the shortcut keys before "Serial Channelx"(x is the channel No.), then changed to the specified serial channel view, as follows:
Figure 5-12 TELNET specified serial channel view
5.7.1 Hostlist
Change to the specified serial channel view, enter the shortcut keys before "Hostlist settings", then changed to the hostlist settings view, as follows:
Figure 5-13 TELNEThostlist settings view
Please refer to the description of the parameters in section . 5-6
CONEXTOP NEPORT User Manual
Chapter 5 TELNET Configuration
5.7.2 Serial Settings
Change to the specified serial channel view, enter the shortcut keys before "Serial settings", then changed to the Serial settings view, as follows:
Figure 5-14 TELNET serial settings view
Please refer to the description of the parameters in section 3.8.
5.7.3 Connection 5.7.3.1 Connection Protocol
Change to the specified serial channel view, enter the shortcut keys before "Connection settings", then changed to the Connection protocol view, as follows:
Figure 5-15 TELNET connection protocol view
5.7.3.2 UDP
Change to the connection protocol view, enter the shortcut keys before "UDP", then changed to the UDP view, as follows: 5-7
CONEXTOP NEPORT User Manual
Chapter 5 TELNET Configuration
Figure 5-16 TELNET UDP view
Please refer to the description of the parameters in section 3.9.2.
5.7.3.3 TCP
Change to the connection protocol view, enter the shortcut keys before "TCP", then changed to the TCP view, as follows:
Figure 5-17 TELNET TCP view
Please refer to the description of the parameters in section 3.9.3.
5.8 Email Settings
Change to the main menu view, enter the shortcut keys before "Email Settings", then changed to the Email view, as follows:
5-8
CONEXTOP NEPORT User Manual
Chapter 5 TELNET Configuration
Figure 5-18 TELNET email view
5.8.1 Email Settings
Change to the email view, enter the shortcut keys before "Email Settings", then changed to the Email settings view, as follows:
Figure 5-19 TELNET email settings view
Please refer to the description of the parameters in section 3.10.
5.8.2 Trigger Settings
Change to the email view, enter the shortcut keys before "Trigger Settings", then changed to the normal email trigger view, as follows:
5-9
CONEXTOP NEPORT User Manual
Chapter 5 TELNET Configuration
Figure 5-20 TELNET normal email trigger view
Please refer to the description of the parameters in section 3.11.
5.8.3 Input Trigger Settings
Change to the email view, enter the shortcut keys before "Input Trigger Settings", then changed to the input email trigger view, as follows:
Figure 5-21 TELNET input email trigger view
Please refer to the description of the parameters in section 3.12.
5.9 SNMP Settings
Change to the main menu view, enter the shortcut keys before "SNMP Settings", then changed to the SNMP view, as follows:
5-10
CONEXTOP NEPORT User Manual
Chapter 5 TELNET Configuration
Figure 5-22 TELNET SNMP view
Please refer to the description of the parameters in section 3.13.
5.10 User Manage
Change to the main menu view, enter the shortcut keys before "User manage", then changed to the user manage view, as follows:
Figure 5-23 TELNET user manage view
There is 5 users for configuration, the first user admin has the administrator privilege and can not be deleted. The others are normal user can be modified and deleted by admin. Change to the user manage view, enter the shortcut keys before "User1", and then changed to the administrator view, as follows:
Figure 5-24 TELNET administrator view
Change to the user manage view, enter the shortcut keys before "Userx"(2-5), then changed to the user view, as follows:
5-11
CONEXTOP NEPORT User Manual
Chapter 5 TELNET Configuration
Figure 5-25 TELNET normal user view
Caution:
The user manage view only appear when admin login.
5.11 Password Setting
Change to the main menu view, enter the shortcut keys before "Password Setting", then changed to the password settings view, as follows:
Figure 5-26 TELNET password settings view
5.12 Load factory default
Change to the main menu view, enter the shortcut keys before "Load factory default", then changed to the load factory view, as follows:
Figure 5-27 TELNET load factory view
5.13 Save and Reboot
Change to the main menu view, enter the shortcut keys before "Save and Reboot", then 5-12
CONEXTOP NEPORT User Manual changed to the save and reboot view, as follows:
Chapter 5 TELNET Configuration
Figure 5-28 TELNET save and reboot view
5.14 View Settings
Change to the main menu view, enter the shortcut keys before "View Settings", then you can view all the settings page by page, press any key to view next page.
Figure 5-29 view the settings
5-13
CONEXTOP NEPORT User Manual
Chapter 6 AT Command
Chapter 6 AT Command
AT command is a set of communication protocols between a host computer and devices. AT originated in the word "Attention", it was first used for communication between terminal and modem, and then latter gradually evolved into industry standards for communications equipment. NEPORT series products expands it, support the use of AT commands to configure device parameters and network connectivity and so on.
6.1 AT commands for parameters setting
Please refer to the CONEXTOP NEPORT AT commands to get the detail description of AT commands.
6.1.1 Basic Settings
command AT!BC AT!BDN AT!BTS Set the name of device Set time related parameters. Table 6-1 AT commands for basic settings contents WEB and TELENT console switch
6.1.2 Network
command AT!EC AT!IC AT!AIC Ethernet settings IP address obtain methods settings Automatically obtain IP address settings Table 6-2 AT commands for network contents
6.1.3 PPPoE
command AT!PC AT!PS PPPoE dial-up settings PPPoE status query
Table 6-3 AT commands for PPPoE
contents
6-1
CONEXTOP NEPORT User Manual
Chapter 6 AT Command
6.1.4 PPP
command AT!PSC AT!PSS PPP dial-up settings query PPP status
Table 6-4 AT commands for PPP
contents
6.1.5 GPRS
command AT!PGC AT!PGS AT!SUP AT!WMSC GPRS dial-up settings GPRS status SIM/UIM card PIN Mobile service center settings
Table 6-5 AT commands for GPRS
contents
6.1.6 Server Settings
command AT!HP AT!SC Set HTTP server port Server settings Table 6-6 AT command for server settings contents
6.1.7 Host list
command AT!HC AT!HHL Host lists retry settings Host lists host settings
Table 6-7 AT commands for host list
contents
6.1.8 Serial Settings
command AT!SP AT!SPP AT!SPPC Serial port properties Serial port packing settings Table 6-8 AT commands for serial settings contents Whether or not to enable serial port
6-2
CONEXTOP NEPORT User Manual
Chapter 6 AT Command
6.1.9 Connection
command AT!CPC AT!CTCR AT!CTDM AT!CTFIB AT!CTFOB AT!CTIT AT!CTUHL AT!TC AT!UDM AT!UDT AT!UMC Connection protocol TCP connection response TCP hard disconnect Clear input buffer settings Clear output buffer settings TCP connection idle time Whether or not enable hostlist function TCP configuration UDP datagram type UDP uni-cast address table UDP multi-cast settings
Table 6-9 AT commands for connection
contents
6.1.10 Email Settings
command AT!REC AT!SEC AT!SMTPC Email receipt settings Email sender settings SMTP server settings Table 6-10 AT commands for email settings contents
6.1.11 Trigger Settings
command AT!ET AT!ETEC Normal email properties
Table 6-11 AT commands for trigger settings
contents Normal email trigger settings
6.1.12 Input Trigger Settings
command AT!EITC AT!EITEC Input trigger mail settings Mail properties triggered by serial input data Table 6-12 AT commands for input trigger settings contents
6-3
CONEXTOP NEPORT User Manual
Chapter 6 AT Command
6.1.13 SNMP
command Contents
Table 6-13 AT commands for SNMP
6.1.14 Password Setting
command AT!UM Use manage
Table 6-14 AT commands for password setting
contents
6.1.15 Special command
command AT!V AT!EXIT AT!LD AT!R AT!S AT!SL Show all the AT command Quit AT command mode Load factory value Save and reset device Save the parameters Enter the serial login mode Table 6-15 special AT command contents
6.2 FTP AT command
NEPORT series supports the use of AT commands for the operation of FTP client, provides traditional industries devices with the FTP client function. Users only need to send AT commands through the serial port, and then can achieve a two-way file transmission between storage systems of the NEPORT series products, FTP servers and local.
Figure 6-1 using AT command for FTP Scenarios
6-4
CONEXTOP NEPORT User Manual
Chapter 6 AT Command
6.2.1 Local and device
command AT!LFOP AT!LFCL AT!LFRD AT!LFWR AT!LFLS Open a file in device Close a file in device opened Read data from device file Write data to device file List all the files in device Table 6-16 AT commands for local and device contents
6.2.2 Local and FTP server
command AT!RCOP AT!RCCL AT!RFOP AT!RFCL AT!RFRD AT!RFWR AT!RFLS contents Open a ftp connection and login from local Close a ftp connection from local Open a file on FTP server from local Close a file on FTP server from local Read data from file on FTP server from local Write data to file on FTP server from local List all the files on FTP server from local
Table 6-17 AT commands for local and FTP server
6.2.3 Device and FTP server
command AT!RCOP AT!RCCL AT!RFPUT AT!RFGET contents Open a ftp connection and login from device Close a ftp connection from device Write data to file on FTP server from device Read data from file on FTP server from device
Table 6-18 AT commands for device and FTP server
6.2.4 Read file procedure
Whether to read file data from the device to the local, or read the file from the FTP server data to local, in addition to differences in the command format, the same process has been followed. First of all, to open the file, and then read from a data file, in order to distinguish between the data blocks, the read file data command must carry the serial number of data blocks, if failed to read, the same piece of data can be read again, prevent the loss of data blocks; close the file when finish, otherwise an error will occur when read and write documents again.
6-5
CONEXTOP NEPORT User Manual
Chapter 6 AT Command
Figure 6-2 using AT command to read data from file
6.2.5 Write to file procedure
The same as reading data from file, whether to write file data to the device, or write the file to FTP server, in addition to differences in the command format, the same process has been followed. First of all, to open the file, and then write data to file, in order to distinguish between the data blocks, the write file data command must carry the serial number of data blocks, if failed to write, the same piece of data can be send again, prevent the loss of data blocks; close the file when finish, otherwise an error will occur when read and write documents again. 6-6
CONEXTOP NEPORT User Manual
Begin
Chapter 6 AT Command
Open file success?
YES Send sequence = 0
Send write file command, waiting for 2s
YES
YES(retransmit)
Return OK
NO
TIMEOUT
YES
NO
Writen length = 0?
Write file abort
NO
Sequence add 1
YES
Continue?
NO
close
end
Figure 6-3 using AT command to write to file
6-7
CONEXTOP NEPORT User Manual
Chapter 7 DeviceManagement
Chapter 7 DeviceManagement
NEPORT series product's DeviceManagement is an excellent device server management tool on PC. You can search and configure the remote NEPORT serial device servers easily. With this utility, you can: Search all the devices on the local network. Configure and view devices' settings. Perform diagnostic tests (with Ping, IE, Telnet). This management utility window is divided into 4 parts (show in 2.2.2.4): The main menu contains the function list and information of this utility. The shortcuts field of function is just below the main menu, you can access the functions more convenient than from the main menu. The devices list view is on the left part below shortcuts field, it shows brief information of devices, and you must select item from it to operate.
7.1 Functions
7.1.1 Menu Items
7-1 main menu of Devicemanagement
7-1
CONEXTOP NEPORT User Manual
Chapter 7 DeviceManagement
7.1.1.1 Operate
Menu item Search Specify Search Config Clear Exit Description Search all the devices in the same LAN, add to list view when found a device. Search for a specified device according to IP address. Query or set configuration of device. Delete all items from the list view control. Quit
Table 7-1 basic operation of Devicemanagement
7.1.1.2 Tools
Menu item IE Telnet Ping Shortcut Key Description Start Internet Explorer to visit the WEB pages of a device selected from the list view. Use Telnet to log in device selected from the list view. Ping the device selected from the list view. Set the shortcut key of operations. Table 7-2 tools of DeviceManagement
7.1.1.3 Language
Menu item English Chinese-Simplified Chinese-Traditional Description Select English as the language of software interface. Select Chinese-Simplified as the language of software interface. Select Chinese-Traditional as the language of software interface. Table 7-3 language of DeviceManagement
7.1.1.4 Help
Menu item About Update About the software. Update software. Table 7-4 Help menu of DeviceManagement Description
7-2
CONEXTOP NEPORT User Manual
Chapter 7 DeviceManagement
7.1.2 Shortcuts Field
Figure 7-2 shortcuts field of DeviceManagement
The shortcuts field is consist of Icons, every Icon stands for a shortcut of a menu item. You can simple click on the Icon instead of clicking on the menu item.
7.1.3 Devices List View
Figure 7-3 device list view of DeviceManagement
Every item in the list view stands for a device in the LAN. It shows the name, IP address, physical address of the device to distinguish each other. When an item is selected, it will be highlighted. You can operate it by menu items, or by shortcuts, or click the right button of mouse then select from the context menu. The content of context menu is the same as the main menu. The details of the menu items is descript in section 7.1.1.
Caution: The IP address and physical address are the features of devices, must different with others, if there is two devices have the same features, unknown problems will occur.
7-3
CONEXTOP NEPORT User Manual
Chapter 7 DeviceManagement
7.2 Configuring Devices
Except WEB and TELNET, you can use the Config function of this software to configure the device. You can execute this function through main menu or context menu, or shortcut of Config, or shortcut key of Config, or just double click on the device item.
7.2.1 Login
Before you can configure the device, maybe you will be prompted to fill use name and password for login as follows:
7-4 login window of DeviceManagement
Fill in with correct user name and password, and then click the Login button to verify.
7.2.2 Configure
If verification is successful, the configuration page is show as follow.
7-4
CONEXTOP NEPORT User Manual
Chapter 7 DeviceManagement
7-5 configuration window of DeviceManagement
The content of configuration page is the same as the WEB page, except some different in layouts and buttons, in the left index column you can click the + to unfold the sub menus, click the - to fold the sub menus. The operation of configuration is also the same as the WEB pages, moreover, you can click the Refresh button to re-retrieve the configuration of device, click the Close button to exit from configuration.
7-5
CONEXTOP NEPORT User Manual NePort Summary
Embedded Seial-IP series Single port series Memory and Speed Flash Code/Boot(KB) SRAM(KB) Speed (MIPS) Core and System Serial Interfaces ARM7TDMI Multi-T RTOS Ethernet Speed (M) Uart RS232 RS485/422 Max-Baudrate(bps) Serial port Number Programmable I/O Protocol stacks PIO Number ARP/IP/ICMP/DHCP /BOOTP/TCP/UDP TFTP SNTP Http Server (web customized) Telnet Server DNS Smtp (Email Trigger) PPP/PPPOE Advanced encryption protocols SSH SSL/TLS Https Smtps Encryption Arithmetic AES DES/Triple-DES RC4 MD5 Analog parameters PowerConsumption (mA) Power suppler(V) I/O Tolerant(V) 10Base-T Activity 100Base-T Activity
+75C I = - 40 - +85C
Chapter 7 DeviceManagement
NePort -L Series NePort-R Series LX 128k /32 80/128 55 Y Y 10/100 Y LX -485 128k /32 80/128 55 Y Y 10/100 Y Y 115200 1 -Y Y -115200 1 2 Y Y ---Y Y(*) Y(*) ----------3.3 5 165 155 C,I RJ45 Y(*) Y(*) ----------3.3 5 165 155 C,I RJ45 Low Cost 460800 1 -Y Y -Y Y Y(*) ----------3.3 5 165 155 C,I RJ45 256k /32 128 55 Y Y 10/100 Y RX RX -485 256k /32 128 55 Y Y 10/100 Y Y 460800 1 2 Y Y -Y Y Y(*) ----------3.3 5 165 155 C,I RJ45
NePort Series SX 512k /32 256 55 Y Y 10/100 Y SX -485 512k /32 256 55 Y Y 10/100 Y Y 460800 1 -Y Y Y Y Y Y Y(*) ---------3.3 5 165 155 C,I RJ45 460800 1 -Y Y Y Y Y Y Y(*) Y(*) --------3.3 5 165 155 C,I RJ45
NePort-EN Series EXH 512k /32 256 60 Y Y 10/100 Y EXH -485 512k /32 256 60 Y Y 10/100 Y Y 921600 1/2/3 -Y Y -Y Y Y ----------3.3 5 165 155 C,I RJ45 921600 1/2/3 2 Y Y Y Y Y Y Y ---------3.3 5 165 155 C,I RJ45 512k /32 256 60 Y Y 10/100 Y Y 921600 1/2/3 2 Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y Y 3.3 5 165 155 C,I RJ45 ESX
Operating temperature arrange
C=0-
Package Option
(RJ45)
Low Cost
7-6
CONEXTOP NEPORT User Manual
Chapter 7 DeviceManagement
More details by: http://www.conextop.com/products/embeddedsolution/wiredmodules/index.htm For details contact your local Conextop representative or Conextop directly: call OEM sales support at 86-755-26505615 More details about NePort at http://www.conextop.com
(c) Conextop Technologies -November 2003 - All rights reserved
The Conextop corporate logo is a registered trademark of Conextop Technology. All other names are the property of their respective owners.
(c)2003 Conextop, Inc. All rights reserved. Conextop, NePort, with its patent-pending technology, and neChip are trademarks of Conextop. All other trademarks are the property of their respective owners. Specifications subject to change without notice. All rights reserved.
7-7